SEA MAX FIRE ENGINEERING WORKS — FIRE ENGINEERING & SAFETY SERVICES
Protecting people, property and business continuity starts with engineering that understands real-world risks. Sea Max Fire Engineering Works delivers full-spectrum fire engineering services for industrial premises, commercial buildings, group housing, hospitals, hotels, data centres and other critical infrastructure. From concept to commissioning and through lifetime maintenance, our engineers and field teams deliver code-compliant, practical fire protection solutions that work in the field — not just on paper.
We combine technical competence with field experience: the same engineers who design systems supervise or review installations; the same teams who maintain systems know how they were built. That continuity reduces surprises, shortens project timelines and produces cleaner handovers that auditors and insurers accept without friction.
We’ll deliver an immediate priority list and a clear proposal showing scope, costs and a realistic timeline for design-to-commissioning. For maintenance customers, we’ll include a baseline health check and a suggested AMC tier with defined SLAs.
OUR CORE SERVICES
What we do: on-site walk-through, occupancy classification, fuel-load quantification, identification of ignition sources, egress capacity checks and verification of existing protection.
Deliverables: illustrated risk assessment report (annotated plans and photographs), prioritised action list, budgeted recommendations and compliance gap report.
Why it’s important: targeted investments and retrofit recommendations based on real site risks — avoids over-specification and supports insurer/regulator discussions.
Scope: conceptual protection scheme through full construction drawings and calculations.
Key outputs: GA drawings, hydraulic calculations for sprinklers & hydrants (head-by-head), agent concentration and discharge calculations for gaseous systems, pipe isometrics, cylinder schedules, electrical release logic and Bill of Quantities (BOQ).
Quality control: all calculations are prepared or reviewed by senior fire engineers and include cited code clauses for transparency.
AMC service tiers (examples):
Basic AMC — quarterly visual checks, extinguisher gauge checks, panel battery inspection.
Standard AMC — monthly visits, quarterly function tests, annual pump flow test and detector cleaning.
Premium AMC — priority 24×7 response, stocked spares, biannual integrity tests and annual pump overhaul.
Refilling & repairs: extinguisher refills (ABC, CO₂, clean agent, K-class), hydrostatic checks where applicable, valve & nozzle replacements and documented service reports.
We supply both in-house manufactured items and certified vendor equipment: portable extinguishers, cylinders, valves, pumps, panels, detectors and foam skids.
Deliverables: purchase traceability (POs), material certificates, factory pressure/test records, pre-assembly checklists and packing lists.
What you get: supervised installation by trained technicians under project engineers, daily QA reports, coordination with civil/MEP trades, safety toolbox talks and on-site tests.
Checks performed: correct hanger spacing, slope & drainage, pipe orientation, valve tagging, loop continuity, polarity & wiring checks for detection/release circuits.
We prepare submission-ready packages and coordinate with your architect/consultant to obtain local fire-authority approvals and NOCs. Documents include evacuation plans, system schematics, equipment datasheets and statutory checklists.
Instrumented acceptance testing: pump curve verification (flow vs pressure), hydrant & sprinkler flow tests, foam proportioner calibration, gaseous system discharge tests and room integrity (leak) tests.
Handover documentation: as-built drawings (CAD + PDF), instrumented commissioning reports, O&M manuals, spare-parts list and signed acceptance certificates.
Types: Clean agent (HFC-227ea, Novec 1230, inert), CO₂ flooding, foam flooding & proportioning, kitchen suppression, tube-based local application and water mist systems.
Deliverables: concentration calculations, cylinder & piping schedule, release circuit design, safety interlocks and room integrity verification.
Solutions: addressable & conventional panels, smoke/heat detectors, flame detectors, manual call points, sounders and BMS integration.
Outputs: detector layout and sensitivity checks, loop diagnostics, interface wiring and sequence of operations.
Design & delivery: sprinkler layouts (wet/dry/pre-action/deluge), hydrant ring mains, hose reels, pump house design (main & jockey pumps), controllers and acceptance testing.
Deliverables: hydraulic calculations, pump test certificates, head-by-head coverage maps and maintenance schedules.
Services: feasibility studies, retrofit plans for legacy systems, value engineered options to meet safety objectives within budgets, and integration strategies for BMS/SCADA and HVAC interlocks.
Programs: practical extinguisher training, fire warden courses, full building evacuation drills, rescue & accountability planning and customized training modules with certificates.
When a fire protection system is installed and commissioned, the job isn’t finished — it’s only begun. At Sea Max Fire Engineering Works we treat repair and maintenance as a continuous engineering discipline: scheduled prevention, timely repair and documentary proof that every component will operate when called upon. Our maintenance approach is practical, auditable and tailored so that systems remain compliant, reliable and cost-efficient for the long term.
At Sea Max Fire Engineering Works we treat fire safety and security as a single, practical discipline: it’s about preventing incidents, limiting harm when they occur, and ensuring people and operations can recover quickly. Our approach is engineering-led, field-proven and client-focused — we don’t sell equipment, we deliver working safety systems and accountable services.
A fire extinguisher is only effective when it is charged, serviced and ready to perform. At Sea Max Fire Engineering Works we treat extinguisher refilling and servicing as a safety-critical engineering task — not a quick swap. Our approach is practical, transparent and auditable: every refill follows a checklist, every cylinder gets the inspections and tests it needs, and every service visit produces documented proof you can rely on for safety audits and insurer queries.
PAGE HIGHLIGHTS (one line)
End-to-end fire engineering: risk assessment, system design, equipment supply, turn-key installation, statutory support, commissioning, training and long-term AMC (Annual Maintenance Contract).
WHY CHOOSE OUR FIRE ENGINEERING SERVICES
• Real experience — designs by fire safety engineers with hands-on commissioning experience.
• End-to-end capability — we supply manufactured products, integrate third-party components and provide disciplined onsite execution.
• Traceable quality — material certificates, factory and commissioning test reports provided with every system.
• Practical compliance — we document the exact code references (IS / NBC / NFPA as applicable) used in each design, which simplifies approvals and audits.
• PAN-India delivery with a strong presence across Delhi NCR, Noida, Gurgaon, Faridabad, Kundli, Sonipat, Panipat, Ghaziabad and adjoining regions.
TEAM & EXPERTISE
Our services are driven by experienced fire safety engineers, project managers and certified technicians. Key strengths:
Design prepared/reviewed by qualified fire engineers.
Field teams trained in pump commissioning, foam calibration and detector loop diagnostics.
Dedicated AMC and refilling teams for rapid response.
CASE STUDIES
Data Centre — Clean agent protection: scope, room integrity results, agent schedule, commissioning summary.
Fuel Storage — Foam proportioner skid & flooding: proportioner design, flow tests, commissioning.
Hotel — Kitchen suppression & alarm integration: sequence of operations and client sign-off.
(Include photos, as-built snippets and client testimonials where permitted.)
TECHNICAL CAPABILITIES & TOOLSET
Hydraulic and sprinkler network design software for accurate flows & pressures.
Agent concentration modelling for gaseous suppression.
Room tightness/blower door testing equipment for integrity checks.
Instrumented pump test rigs and digital flow/pressure logging.
CAD/BIM deliverables and O&M manual templates.
QUALITY CONTROL, STANDARDS & COMPLIANCE
We design and document to recognised codes and best practice: Indian Standards (IS), the National Building Code (NBC) and NFPA guidance where applicable (NFPA 13/20/72/2001 etc.). For each project we provide:
Material certificates and factory test records.
Commissioning & instrumented test reports.
Explicit code clause references used in calculations and drawings (helps statutory approvals and insurer acceptance).
TYPICAL APPLICATIONS & SECTORS
Data centres & telecom rooms (clean agent systems & early detection)
Hospitals & medical facilities (compartmentation, detection, redundant systems)
Hotels & restaurants (kitchen suppression, alarm integration)
Manufacturing, chemical & fuel storage (foam systems, hydrants)
Warehouses & logistics hubs (sprinklers, hydrants & exit planning)
Residential high-rise & commercial offices (doors, signage, evacuation)
COMMON QUESTIONS (FAQ)
Q: What is included in a site survey?
A: Visual inspection, hazard mapping, basic measurements, photographs, preliminary recommendations and a checklist for full design requirements.
Q: How long does design to commissioning take?
A: Small systems (single room suppression) typically 2–4 weeks after design approval. Medium projects (sprinkler + pump) 4–8 weeks. Large industrial packages depend on equipment lead times and civil work — we provide a project schedule in the proposal.
Q: Do you provide statutory submission drawings?
A: Yes — we prepare submission-ready drawings and coordinate with local fire authorities and architects.
Q: Are your technicians available 24/7 for emergencies?
A: Priority response is included in Premium AMC; otherwise emergency callouts are available and billed as per the contract.
Q: Can you retrofit sprinklers or modern detection in older buildings?
A: Yes — we perform gap analysis and propose minimally disruptive retrofit solutions with phased implementation.
DOCUMENTATION & HANDOVER PACKAGE (STANDARD)
Each major project receives a full handover pack:
As-built drawings (CAD + PDF)
Operation & Maintenance Manual (O&M)
Commissioning & test reports (pump curves, flow/pressure logs)
Spare parts list and recommended inventory
Signed training & handover certificates
AMC schedule and warranty terms
DETAILED DELIVERABLES
For every major system we deliver:
Design pack: drawings, calculations, BOQ.
Procurement pack: material certificates & vendor test reports.
Installation & QA logs.
Commissioning report with instrumented test results.
Operation & Maintenance manuals + spare parts list.
On-site training records and scheduled AMC plan.
SERVICE AREAS
We operate PAN-India with strong operations in: Delhi NCR, Noida, Gurgaon, Faridabad, Kundli, Sonipat, Panipat, Ghaziabad and surrounding regions. For remote projects we provide logistics and project management support to ensure timely delivery.